summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorPaul Buetow <paul@buetow.org>2026-05-29 17:36:18 +0300
committerPaul Buetow <paul@buetow.org>2026-05-29 17:36:18 +0300
commit6f0280a5ff32dce9d32758bfda52e0be7eb17b34 (patch)
tree8ed3fb324744fe6ca9725517e92f1de425897146
parent372d01873ccdc7db9a076c12577d5b1ab6288d10 (diff)
test(generate): lock in init_module vs finit_module classification
Audit of init_module (man 2 init_module) confirmed the implementation is correct: init_module(void *module_image, unsigned long len, const char *param_values) is classified KindModule (null_event), capturing neither an fd nor a path — param_values is a module-parameter string, not a filesystem path. finit_module(int fd, ...) is classified KindFd via field-based matching and captures fd = args[0]. Both syscalls live in the Security family and match docs/syscall-tracing-plan.md. No explicit finit_module test or init_module-vs-finit_module distinction test existed, so add lock-in coverage: - testdata.go: real-layout Format constants for (f)init_module enter/exit. - classify_test.go: assert init_module=KindModule with no PathnameField and finit_module=KindFd. - codegen_test.go: assert generated BPF C for init_module captures no fd and no filename/path, while finit_module captures fd = args[0]. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
-rw-r--r--internal/generate/classify_test.go26
-rw-r--r--internal/generate/codegen_test.go24
-rw-r--r--internal/generate/testdata.go69
3 files changed, 119 insertions, 0 deletions
diff --git a/internal/generate/classify_test.go b/internal/generate/classify_test.go
index fecbb93..b03164b 100644
--- a/internal/generate/classify_test.go
+++ b/internal/generate/classify_test.go
@@ -1022,6 +1022,32 @@ func TestClassify67NameOnlyKinds(t *testing.T) {
}
}
+// TestClassifyInitModuleVsFinitModule locks in the load-bearing distinction
+// between the two module-loading syscalls (man 2 init_module).
+//
+// init_module(void *module_image, unsigned long len, const char *param_values)
+// takes a userspace ELF image pointer and a module-PARAMETER string (not a
+// filesystem path), so it must classify as KindModule (null_event) and capture
+// neither an fd nor a path — param_values must NOT be mistaken for a path.
+//
+// finit_module(int fd, const char *param_values, int flags) reads the module
+// from a file descriptor, so it must classify as KindFd via field-based
+// matching on the leading "fd" field.
+func TestClassifyInitModuleVsFinitModule(t *testing.T) {
+ if r := classifyFromData(t, FormatInitModule); r.Kind != KindModule {
+ t.Errorf("init_module: got kind %d, want KindModule", r.Kind)
+ }
+ if r := classifyFromData(t, FormatFinitModule); r.Kind != KindFd {
+ t.Errorf("finit_module: got kind %d, want KindFd", r.Kind)
+ }
+
+ // param_values (uargs) is a parameter string, never a captured path: the
+ // init_module classification must not select KindPathname/KindName/KindOpen.
+ if r := classifyFromData(t, FormatInitModule); r.PathnameField != "" {
+ t.Errorf("init_module: unexpected PathnameField %q, want empty", r.PathnameField)
+ }
+}
+
func TestClassify87NameOnlyKinds(t *testing.T) {
tests := []string{
"sys_enter_rt_sigaction",
diff --git a/internal/generate/codegen_test.go b/internal/generate/codegen_test.go
index 746aa07..6b19129 100644
--- a/internal/generate/codegen_test.go
+++ b/internal/generate/codegen_test.go
@@ -24,6 +24,30 @@ func TestGenerateFdHandler(t *testing.T) {
requireContains(t, output, "#define SYS_ENTER_READ 844")
}
+// TestGenerateModuleHandlers locks in the generated BPF C for the module-load
+// syscalls (man 2 init_module). init_module is a null_event: it must capture no
+// fd and no path/filename (its param_values arg is a parameter string, not a
+// path). finit_module is an fd_event capturing fd = args[0].
+func TestGenerateModuleHandlers(t *testing.T) {
+ initOut := generateFromPair(t, FormatInitModule, FormatExitInitModule)
+ requireContains(t, initOut, `SEC("tracepoint/syscalls/sys_enter_init_module")`)
+ requireContains(t, initOut, "struct null_event *ev = bpf_ringbuf_reserve(&event_map, sizeof(struct null_event), 0);")
+ requireContains(t, initOut, "ev->event_type = ENTER_NULL_EVENT;")
+ // init_module must not capture an fd or any filename/path.
+ if strings.Contains(initOut, "ev->fd =") {
+ t.Error("init_module handler must not capture an fd")
+ }
+ if strings.Contains(initOut, "ev->filename") || strings.Contains(initOut, "bpf_probe_read_user_str") {
+ t.Error("init_module handler must not capture param_values as a path/filename")
+ }
+
+ finitOut := generateFromPair(t, FormatFinitModule, FormatExitFinitModule)
+ requireContains(t, finitOut, `SEC("tracepoint/syscalls/sys_enter_finit_module")`)
+ requireContains(t, finitOut, "struct fd_event *ev = bpf_ringbuf_reserve(&event_map, sizeof(struct fd_event), 0);")
+ requireContains(t, finitOut, "ev->event_type = ENTER_FD_EVENT;")
+ requireContains(t, finitOut, "ev->fd = (__s32)ctx->args[0];")
+}
+
func TestGeneratePidfdGetfdHandlerUsesPidfdArgument(t *testing.T) {
output := generateFromPair(t, FormatPidfdGetfd, FormatExitPidfdGetfd)
diff --git a/internal/generate/testdata.go b/internal/generate/testdata.go
index 50efc00..8c2b1ee 100644
--- a/internal/generate/testdata.go
+++ b/internal/generate/testdata.go
@@ -1208,6 +1208,75 @@ format:
print fmt: "0x%lx", REC->ret
`
+// FormatInitModule mirrors the real sys_enter_init_module tracepoint layout.
+// Its arguments are a userspace ELF image pointer (umod), the image length
+// (len), and a module-parameter string (uargs). uargs is a parameter string of
+// the form "name=value ..." — NOT a filesystem path — so init_module must
+// classify as KindModule (null_event) and capture neither an fd nor a path.
+const FormatInitModule = `name: sys_enter_init_module
+ID: 9370
+format:
+ field:unsigned short common_type; offset:0; size:2; signed:0;
+ field:unsigned char common_flags; offset:2; size:1; signed:0;
+ field:unsigned char common_preempt_count; offset:3; size:1; signed:0;
+ field:int common_pid; offset:4; size:4; signed:1;
+
+ field:int __syscall_nr; offset:8; size:4; signed:1;
+ field:void * umod; offset:16; size:8; signed:0;
+ field:unsigned long len; offset:24; size:8; signed:0;
+ field:const char * uargs; offset:32; size:8; signed:0;
+
+print fmt: "umod: 0x%08lx, len: 0x%08lx, uargs: 0x%08lx", ((unsigned long)(REC->umod)), ((unsigned long)(REC->len)), ((unsigned long)(REC->uargs))
+`
+
+const FormatExitInitModule = `name: sys_exit_init_module
+ID: 9369
+format:
+ field:unsigned short common_type; offset:0; size:2; signed:0;
+ field:unsigned char common_flags; offset:2; size:1; signed:0;
+ field:unsigned char common_preempt_count; offset:3; size:1; signed:0;
+ field:int common_pid; offset:4; size:4; signed:1;
+
+ field:int __syscall_nr; offset:8; size:4; signed:1;
+ field:long ret; offset:16; size:8; signed:1;
+
+print fmt: "0x%lx", REC->ret
+`
+
+// FormatFinitModule mirrors the real sys_enter_finit_module tracepoint layout.
+// Unlike init_module, finit_module reads the module from a file descriptor
+// (fd at args[0]), so field-based classification must yield KindFd and capture
+// fd = args[0]. This is the load-bearing distinction from init_module.
+const FormatFinitModule = `name: sys_enter_finit_module
+ID: 9371
+format:
+ field:unsigned short common_type; offset:0; size:2; signed:0;
+ field:unsigned char common_flags; offset:2; size:1; signed:0;
+ field:unsigned char common_preempt_count; offset:3; size:1; signed:0;
+ field:int common_pid; offset:4; size:4; signed:1;
+
+ field:int __syscall_nr; offset:8; size:4; signed:1;
+ field:int fd; offset:16; size:8; signed:0;
+ field:const char * uargs; offset:24; size:8; signed:0;
+ field:int flags; offset:32; size:8; signed:0;
+
+print fmt: "fd: 0x%08lx, uargs: 0x%08lx, flags: 0x%08lx", ((unsigned long)(REC->fd)), ((unsigned long)(REC->uargs)), ((unsigned long)(REC->flags))
+`
+
+const FormatExitFinitModule = `name: sys_exit_finit_module
+ID: 9372
+format:
+ field:unsigned short common_type; offset:0; size:2; signed:0;
+ field:unsigned char common_flags; offset:2; size:1; signed:0;
+ field:unsigned char common_preempt_count; offset:3; size:1; signed:0;
+ field:int common_pid; offset:4; size:4; signed:1;
+
+ field:int __syscall_nr; offset:8; size:4; signed:1;
+ field:long ret; offset:16; size:8; signed:1;
+
+print fmt: "0x%lx", REC->ret
+`
+
const FormatAccept = `name: sys_enter_accept
ID: 1808
format: